Operating voltage |
230V AC +/-10%, 50/60 Hz or
115V AC +/-10%, 50/60 Hz |
Relay contacts |
2 voltage-free make-contacts |
max. switching current |
each 12 A AC1 |
max. switching voltage |
250 V ~ |
Display |
13 mm LED - Display, 3 digits |
Display range |
-99 .. 999 |
Temperature resolution |
0,1°C |
Sensor type |
KTY 81-210 |
Sensor cable lenght |
2 metres (or as required) |
Measurement range |
-5° .. +70°C |
Target temperatur T1*
Target temperatur T2* |
factory-set to 8°C
factory-set to 4°C |
Control type |
two-step regulator |
Hysteresis* |
0,1 K to 99,9 K
(standard adjusting 0,7 K) |
Stirrer
- resting time (interval) *
- stirring time * |
factory-set to 20 min.
factory-set to 2 min.
|
Housing
- front dimension
- front panel cut out
- insertion depht
|
68 x 106 mm
56 x 87 mm
45 mm
|
Protection (housing front)
|
IP 65 |
Connection |
Screw terminals |
Environment specifications:
- Operation temperature
- Storage temperature
- max. humidity |
0° .. +50°C
-20° .. +70°C
75% (no dew)
|
* freely adjustable |